MEH-60-P series

CAD data download
(DXF)
*Under construction
CATALOGUE
data download
(PDF)
MEH-60-P series




MEH-60-P seriesSOO`¡-@}
  Type name
Item  

MEH-60-P

Supply voltage open collector : DC5V to 12V±10%
DC5V±10%
(20250 pulse or more)
open collectorDC24V : DC24V±10%
Line driver : DC5V±5%
Current consumption 60mAor less *120mA or less (under no load)
Detection system Incremental
Output pulse number
(Standard)
(Pulse number/rotation)
100
180
200
360
400
500
600
1000
1024
1800
2000
3600
4000
5000
5400
8100
9000
10000
10800
*20250
*21600
Output phase A, B, Z phase
Output form Square wave
Output capacity Sink current: 20mA
Residual voltage: 0.5V or less (at 10mA)
Maximum response frequency
(response pulse number)
100kHz
Output phase difference A, B phase difference 90°±45°(T/4±T/8)
Z phase T±T/2 (see Output Waveform)
Waveform rise/fall time 2s or less
(output cable 1m or less)
Starting torque 20x10-3Nm(200gfcm)or less
(no oil seal)
Allowable load of
shaft (electrical)
Radial 19.6N(2kgf) 9.8N(1kgf)
Thrust 9.8N(1kgf) 4.7N(0.5kgf)
Maximum allowable revolutions
(mechanical)
3000r/min
Working ambient temperature/
humidity
0 to 60
RH35% to 90% no dewing
Storing ambient temperature -20 to 80
Vibration resistance Durability 55Hz, double amplitude 1.5mm
2 hours each in X, Y, and Z directions
Impact resistance Durability 500m/s2 (about 50G)
3 times each in X, Y, and Z directions
Cable Outside diameter 4.2 5-core vinyl wire
Insulated shield cable (length 1m)
Mass 320g *430g



A capacitor (0.1F) is connected between 0V and FG (frame ground).

Specifications/Sine wave
Supply voltage DC5V ±5%
Current consumption 40mA or less
(under no load)
Detection system Sine waveIncremental
Output pulse number
(Standard)
(Pulse number/rotation)
5000
9000
10000
*20250
*21600
Output phase A, B, Z phase
Output form A,B phase SIN wave, Z phase square wave
A,B,Z phase output SIN wave 1.5 Vp-p±0.3 V offset 2.0V±0.2V
Opamp output current 5mA Max.
Harmonic distortion factor to be within 10%
(Measuring condition to be within 20 kHz,
effective value mean distortion factor measuring instrument)
Maximum response frequency 50kHz
Output phase difference A, B phase difference 90±45(T/4±T/8)
Z phase T±T/2 (see Output Waveform)
Starting torque 20x10-3Nm(100gfcm) or less
Allowable load of
shaft (electrical)
Radial 14.7N (1.5kgf)
Thrust 4.9N (0.5kgf)
Maximum allowable revolutions
(mechanical)
3000r/min
Working ambient temperature/
humidity
0 to 50
RH35% to 90% no dewing
Storing ambient temperature -20 to 80
Vibration resistance Durability 55Hz, double amplitude 1.5mm
2 hours each in X, Y, and Z directions
Impact resistance Durability 500m/s2 (about 50G)
3 times each in X, Y, and Z directions
Cable Outside diameter 4.2 5-core vinyl wire
Insulated shield cable (length 1m)
Mass 320g *430g



Supply voltage Voltage:DC5V-5%~12V+10%
Open collector:DC5V-5%~24V+10%
Open collector output:20,250, 21,600:DC5V-5%
Line driver:DC5V±5%
Current consumption 80mA or less
(under no load)
Detection system Incremental
Output pulse number
(Standard)
(Pulse number/rotation)
EX 21,600×2(43,200)
21,600×4(86,400)
21,600×8(172,800)
21,600×16(345,600)
Output phase A, B, Z phase
Output form Square wave
Maximum response frequency
Line driver output:50kHz× (by multiplication)
Voltage output·Open collector output:100kHz
Output phase difference See the diagram below.
Starting torque 20x10-3Nm(200gfcm) or less
Allowable load of
shaft (electrical)
Radial 9.8N (1kgf)
Thrust 4.9N (0.5kgf)
Maximum allowable revolutions
(mechanical)
3000r/min
Working ambient temperature/
humidity
-10 to 70
RH35% to 90% no dewing
Storing ambient temperature -20 to 80
Vibration resistance Durability 55Hz, double amplitude 1.5mm
2 hours each in X, Y, and Z directions
Impact resistance Durability 500m/s2(about 50G)
3 times each in X, Y, and Z directions
Cable Outside diameter 4.2 5-core vinyl wire
Insulated shield cable (length 1m)
Mass 430g



BACK