MGH series


MGH series
MGH-20 Pulse number 100 to 200 250 to 600 800 to 1200
MGH-30 Pulse number 100 to 300 400 to 1024 1200 to 2000
Allowable
eccentricity
Radial ±0.05mm ±0.02mm
Thrust ±0.2mm ±0.1mm ±0.05mm

  Type name
Item  

MGH-20
--E

MGH-30
--E

Supply voltage DC+5V±10%
Current consumption 60mA or less (under no load)
Detection system Incremental
Output pulse number
(Standard)
(Pulse number/rotation)
40
50
60
100
200
250
256
300
360
400
450
500
*500
512
600
800
1000
*1000
*1024
1200
40
50
60
100
200
250
300
360
400
450
500
600
800
1000
*1000
1024
*1024
1200
1500
1800
2000
*2000
Output phase
Output form Square wave Line driver output
Output capacity V0L=0.5Vmax
V0H=2.5Vmin
I0=±20mA
Maximum response frequency
(response pulse number)
150kHz
Output phase difference A, B phase difference 90°±45°(T/4±T/8)
Z phase T±T/2 With CS signal (U, V, W)
4 poles, 120° phase difference 3 signals
Waveform rise/fall time 2s or less
Maximum allowable revolutions
(mechanical)
6000r/min
Working ambient temperature/
humidity
-10 to 80
RH35% to 90% no dewing
Storing ambient temperature -20 to 80
Vibration resistance Durability 55Hz, double amplitude 1.5mm
2 hours each in X, Y, and Z directions
Impact resistance Durability 500m/s2
(about 50G)
3 times each in X, Y, and Z direction
Cable Outside diameter 4.2 (6,8) 8-core(19-core) vinyl wire
Insulated shield cable length 1m (length 0.5m)
Mass 60g 100g