MLS-30 series

CAD data download
(DXF)
*Under construction
CATALOGUE
data download
(PDF)
MLS-30 series


MLS-30 series

Type name

MLS-
30-
01-
500

MLS-
30-
01-
1000

MLS-
30-
001-
500

MLS-
30-
001-
1000

Measuring range mm 500 1000 500 1000
Output pulse/1mm 10 10 100 100
Counter accuracy pulse ±1 ±1 ±1 ±1
Minimum reading 0.1 0.1 0.01 0.01
Power AC100V 50/60Hz 180mA max
Counter mode 10 Decimal
Count indication 0 to ±999999.9 0 to ±99999.99
Reset Reset switch provided *External signal resetting possible
External output *BCD parallel output
Mass 700g
Power cord 2m with plug
Note: For counter specifications, see DC Series. *indicates option.

Type name

Item

MLS-
30-
450-
500

MLS-
30-
450-
1000

MLS-
30-
4500-
500

MLS-
30-
4500-
1000

Measuring range mm 500 1000 500 1000
Output pulse/1mm 5 5 50 50
Stroke speed mm/sec 1000 1000 1000 1000
Absolute accuracy mm ±0.25 ±0.5 ±0.25 ±0.5
Minimum resolution mm 0.2 0.2 0.02 0.02
Supply voltage DC5 to 12Vą10%
DC24Vą10%
DC5 to 12V±10%
Current consumption 60mA or less (under no load)
Output phase A phase, B phase
Output form Square wave
Output capacity Sink current 20mA or less, residual voltage 0.5V or less (at 10mA)
Response frequency 50kHz
Output phase A, B phase difference 90±45
Waveform rise/fall time 2  sec or less
Wire tensile force 1.4N to 2.9N (150 to 300gf)
Working ambient
temperature/humidity
0 to 50/RH35% to 90%
Storage ambient temperature -20 to 80
Vibration resistance Endurance 10 to 55Hz Double amplitude 2 hours each in X, Y, and Z directions
Impact resistance 50G
Cable Insulated shield wire Outside diameter 4.2 4-core vinyl wire
Mass 185g
Note: The output pulse or resolution is possible to 4 multiple with the counter.


A capacitor (0.1F) is connected between 0V and FG (frame ground).


BACK